SETTING FIXTURE
FEATURES OF SETTING FIXTURE
- Compact design.
- Easy set up operation.
- Insert is adjusted from the cutting edge point therefore runout accuracy is high.
SETTING FIXTURE STANDARD
| Order Number |
R |
L |
W |
H |
h1 |
Cutting Diameter |
| SEF500 |
315 |
600 |
400 |
347 |
247 |
-ø500 |
| SEF700 |
400 |
800 |
500 |
380 |
280 |
ø315-ø700 |
- (Note.1)
- Please specify the order number when ordering.
- (Note.2)
- Please contact us regarding special spare parts order.
Method of Insert
Setting for
One Piece Type. |
|
- Set the needle using the hight gauge which is the same height as the cutter.
- Move the needle to an insert.
- Slide the insert to the point where it touches the needle. Tighten all the inserts lightly.(Use torque wrench.)(1-2Nm)
*Screwing the inserts too tightly results in lower accuracy.
|
|
- After temporary tightening, use torque wrench to tighten firmly. (Use torque wrench.) (8Nm)
- Screw the inserts tightly according to the picture shown on the left.
- Check runout of all the inserts with a dial gauge.
*For general milling, < 10µm is the standard.
*For finishing, set the insert run out at < 5μm.
|
Method of Insert
Setting for
Two Piece Type. |
|
- Set the height gauge at the same height as the cutter on the liners of slider, then set the needle.
- Put the cutter on the liners of the slider and move the rollers of the
slider to the installation holes.
- Make sure that the three rollers are free, then fix the sliders.
*Process of tightening inserts is the same as one piece type.
|
- Note
-
- After machining, dust off chips on the cutter with air before loosening the wedge.
- When loosening clamp screws, avoid using a damaged wrench.
- Alien substances attched to inserts lowers runout accuracy and damages the cutter body. Therefore, they need to be cleaned throughly.
- After all the inserts are taken out, clean the cutter body with oil or strong air blow.
- Use a torque wrench or special wrench for tightening the clamp screws.